4 Attach the interface card to the controller board.
a Position the interface card so that its I/O connector slides into its opening in
the interface panel and that its 80-pin connector aligns with the 80-pin
connector on the controller board.
b Gently press the interface card down until its connector is fully seated and the
card is secured by the plastic support post(s).
Caution:
Make sure that the connectors on the interface card and controller
board are properly aligned. Damage to the interface card and/or controller
board could result if the pins are misaligned.
5 Secure the interface card to the interface panel with the two screws you
removed earlier.
6 Reinstall the controller board.
Gently slide the controller board into the printer until it is fully seated, and then
tighten the two screws.
7 Reconnect all interface cables.
8 Reconnect the power cord, and turn on the printer.
9 Print a start-up page.
Check that the start-up page lists the interface just installed under “Options.”
...................................................
...................................................